logo_top_vn
banner_vnt
< Back (go to the products section)
line
Thumbnail image
CIATIM-201 (GOST 6267-74)

Analogues: Era, Zimol, Lito, CIATIM-221

Application: Friction units working with a small shear force at low loads, aviation equipment, radio equipment, electromechanical and other devices and precision mechanisms. Satisfactory mechanical stability, low colloidal stability, frost and water-resistance.

Operate at temperatures from minus 60 to plus 90 Celsius degree.

Low viscosity petroleum oil thickened with lithium stearate; the grease contains an antioxidant additive.



GOST 6267-74 CIATIM-201 grease. Specifications (with Changes N 1-4)

 

 

International standard

CIATIM-201 grease

Specifications


 

Information data

1. Developed and submitted by the Ministry of oil refining and petrochemical industry of the USSR.

2. Approved and put into effect by the Resolution of the State Committee of the USSR on standards of 25.07.74 № 1770.

3. Instead of GOST 6267-59.

4. Reference regulatory and technical documents

 

The designation of the reference document, which is given the link

Paragraph number

GOST 9.080-77

1.3

GOST 111-90

3.2

GOST 859-2001

3.3, 3.4

GOST 1510-84

4.1, 5.1

GOST 2477-65

1.3

GOST 2517-85

2.2, 3.1

GOST 5346-78

1.3

GOST 5734-76

1.3

GOST 6479-73

1.3

GOST 6707-76

1.3

GOST 6793-74

1.3

GOST 7142-74

1.3

GOST 7143-73

1.3

GOST 7163-84

1.3

GOST 9566-74

1.3

GOST 23258-78

Introduction part

5. The term limit was lifted under Protocol N 4-93 of the Interstate Council for standardization, metrology and certification (IUS 4-94).

6. Edition with Changes N1,2,3,4 approved in March of 1980, in September of 1984, in April 1990 (ИУС 4-80, 12-84, 1-90, 7-90).

This standard applies to the frost-resistant grease CIATIM-201 designed for lubrication of low-loaded rolling and sliding friction units at temperatures from minus 60 to 90 Celsius degree.

The designation of the grease according GOST 23258 – NLi6/9-1.

(Revised version, Ed. N 2, 3)

 

 

1. Specifications

1.1 (Excluded, Ed. N 4)

1.2 The grease must comply with the requirements of this standard and be produced according to the technology was applied in the development of prototype greases that have passed the tests with positive results and approved to use in accordance with the established order.

1.3 According to physical and chemical indicators, the grease must comply with the requirements and standards are represented in the table:

 

Indicator name

Standard

Test method

1. Appearance

Homogeneous ointment without lumps, from light yellow to light brown color.

According to paragraph 3.2.

2. Effective viscosity at minus 50 Celsius degree and an average strain rate gradient of 10 sec., Pa-s, no more than

1100

According to GOST 7163

3. Tensile strength at 50 Celsius degree, Pa

250-500

According to GOST 7143

4. Drop-off temperature Celsius degree, not lower

175

According to GOST 6793

5. Colloidal stability, % of the released oil, no more than

26

According to GOST 7142

6. Corrosion effects on metals

It withstands

According to GOST 9.080 with the addition according of clause 3.3 this standard

7. Stability against oxidation, mg KON per 1 gram of the grease, no more than

3

According to GOST 5734 with change according of clause 3.4 this standard

8. Free alkali contents, in terms of NaOH, %, no more than

0.1

According to GOST 6707

9. Water contents

Absence

According to GOST 6479

10. Mechanical impurities contents

According to GOST 9566

11. Evaporability in cups-evaporators at 120 Celsius degree, 1 hour, %, no more than

25

According to GOST 9566

12. Penetration at 25 Celsius degree

Its’ not rated

According to GOST 5346

Notes. (Excluded, Ed. N 3).

 

(Revised version, Ed. N 1, 2, 3).

2. Acceptance rules

2.1 The grease is taken in batches. The batch is considered to be the amount of grease weighing up to 11 tons of simultaneous production, uniform in its quality indicators and accompanied by a single quality document.

(Revised version, Ed. N 2, 3)

2.2 The volume of samples - according to GOST 2517.

2.3 If unsatisfactory test results are obtained for at least by one of the parameters, repeat tests are performed on a newly selected sample from the same sample.

Results of repeated tests are distributed to the entire batch.

(Revise version, Ed. N 2,3)

2.4 Penetration is determined only when supply of grease to the export.

(Entered additionally, Ed. N 1)

3. Test methods

3.1 The grease sample is taken in accordance to GOST 2517.

For the combined sample, take 1.5 kg of grease.

3.2 To determine the appearance, the grease is applied with a spatula on a plate of size 50x70x2 mm. glass in accordance with GOST 111 using a template (inner dimensions 35x35x2 mm.) and viewed in passing light.

3.1-3.2 (Revised version, Ed. N 2)

3.3 The corrosion effects on metals is determined on the plates made of copper grades M0k or M1k in accordance with GOST 859.

3.4 The stability test against oxidation is carried out on the plates made of copper grades M0k or M1k in accordance with GOST 859.

3.3, 3.4 (Revised version, Ed. N 1)

4. Packing, labeling, transportation and storage

4.1 Packing, labeling, transportation and storage of the grease carried out in accordance with GOST 1510 with the following additions: the grease is packed in banks made of white tin with a capacity of up 1 WIR tubes up to 250 cm the grease must be stored in the manufacturer’s container.

5. Manufacturer’s guarantee

5.1 The manufacturer guarantees the conformity of the grease with requirements of this standard if the storage and transportation conditions stipulated by GOST 1510 and this standard are met.

(Revised version, Ed. N 3)

5.2 The warranty period for storing the grease storage is 5 years from the day of manufacture.

(Revised version, Ed. N 2)

6. Safety requirement

6.1 The grease isn’t toxic. Special safety instructions when working with the grease are not required.

6.2 When working with the grease it’s necessary to use personal protective equipment according to typical industry standards approved in the established order.

(Revised version, Ed. N 3)

6.3 When the grease ignites all fire extinguishing means are applicable, except water.


 
Joomla SEO powered by JoomSEF